Pioneer SD-1000 specifications

Category : Oscilloscopes

Brand : Pioneer

General

Connections

Tech nical data

Special equipment

  • Manufacturer: Pioneer
  • Model: SD-1000 (in Japan SD-100)
  • Type: Stereo Oscilloscope
  • < li>Years of construction: 1971 - 1972
  • Manufactured in: Japan
  • Color: Wood / Metal Silver / Display Plexiglass Black
  • Type: Stereo Oscilloscope
  • Power consumption: 25 Watts (max.)
  • Dimensions: 430 x 145 x 348 mm (WxHxD)
  • Weight: 8.8 kg.
  • factory price approx.: 108'000 Yen (Japan, 1971), 550 US-$ (~2'200 DM)
  • number of inputs:
    • input terminals Front: 3
      • input 1 (Vertical)
      • input 2 (Horizontal)
      • microphone (Mono), sensitivity of 0.6 mV, 50 k643961b8da111c0a15d770a1109a86d4 at 1 kHz
    • inputs Rear: 6
      • inputs 1, 2, 3, 4
      • FM Multipath Vertical
      • FM Multipath Horizontal
  • number of outputs: 1
    • output Front: AF OSC synthesizer
  • input terminals Front: 3
    • input 1 (Vertical)
    • input 2 (Horizontal)
    • microphone (Mono), sensitivity of 0.6 mV, 50 k643961b8da111c0a15d770a1109a86d4s at 1 kHz
  • inputs Rear: 6
    • inputs 1, 2, 3, 4
    • FM Multipath Vertical
    • FM Multipath Horizontal
  • input 1 (Vertical)
  • input 2 (Horizontal)
  • microphone (Mono), sensitivity of 0.6 mV, 50 k643961b8da111c0a15d770a1109a86d4 at 1 kHz
  • inputs 1, 2, 3, 4
  • FM Multipath Vertical
  • FM Multipath Horizontal
  • output Front: AF OSC synthesizer
  • scope:
    • Braun tube 75mm (electrostatic type)
  • Vertical deflection:
    • sensitivity: 20 mV P-P/cm
    • frequency range: 5Hz - 250kHz (< -3dB)
    • input impedance: 190kohm
  • Horizontal deflection:
    • sensitivity: 20 mV P-P/cm
    • frequency range: 5Hz - 250Hz (< -3dB)
    • input impedance: 190kohm
  • frequency amplitude of the sample path (4 areas): 10Hz - 100kHz
  • synchronous circuit: > 3/8 Inch on the screen
    • Internal synchronization system
  • additional circuit:
    • point-Killer circuit
  • Braun tube 75mm (electrostatic type)
  • sensitivity: 20 mV P-P/cm
  • frequency range: 5Hz - 250kHz (< -3dB)
  • input impedance: 190kohm
  • sensitivity: 20 mV P-P/cm
  • frequency range: 5Hz - 250Hz (< -3dB)
  • input impedance: 190kohm
  • Internal synchronization system
  • point-Killer circuit
  • sound:
    • frequency range: 20 - 20000 Hz
    • output voltage: 2V or more, adjustable
    • frequency response: 20 - 20000 Hz, < ± 1 dB
    • output impedance: < 4.7 k643961b8da111c0a15d770a1109a86d4
    • Harm. Distortion: < 1% (20 - 20000 Hz)
    Frequency range: 20 - 20000 Hz
  • Output voltage: 2V or more, adjustable
  • Frequency response: 20 - 20000 Hz, < ± 1 dB
  • Output impedance: < 4.7k643961b8da111c0a15d770a1109a86d4< /li>
  • Harm. Distortion: < 1% (20 - 20000 Hz)
  • Output meter:
    • Reference range: 0 dB at 2V
    • Input sensitivity, switchable: 0 dB, -10 dB, -20 dB
    • Setting time: < 0.3 seconds at 0 dB, at 1 kHz
    • Frequency range: 20 - 20000 Hz ± 1 dB
  • Reference range: 0 dB at 2V
  • Input sensitivity, switchable: 0 dB, -10 dB, -20 dB
  • Setting time: < 0.3 seconds at 0 dB, at 1 kHz
  • Frequency range: 20 - 20000 Hz ± 1 dB
  • Microphone connection Front for measuring microphone
  • Level control Back for picture tubes Focus and intensity
  • The first version of the classic (and rare) test instrument from Pioneer . It integrated an oscilloscope with waveform/Lissajous/FM multipath display options and combines that with dual (V/H or L/R) level meter. The SD-1000 is not quite as versatile in quad display/analysis functions as the next version SD-1100, but it is a classic design and a very useful (and attractive) test instrument.
  • The device has an integrated frequency generator, for sweep and sine. 4 separately controllable inputs. You can have waveforms displayed.
  • The level meters are in a pre-Silver Aera color scheme of green/orange with a black fascia.
  • The SD-1000 is a stereo display device that can synthetically observe and measure acoustic properties such as various waves and also sound field properties of a listening room.
  • A tuner with multipath output can be connected and the orientation of the antenna can be optimized more easily.
  • Two large-sized level meters can be used for power and voltage measurement as well as as a VU level meter.
  • The input terminal for 4-channel is also prepared.
  • The device is also equipped with a broadband frequency amplifier for a mono microphone. In this way, the sensitivity, the acoustic frequency response and the characteristics of the speaker system can be checked with an electret condenser microphone. The Pioneer microphone was optionally available as type Pioneer CM-01.
  • Other models of the same series:
  • Pioneer SD-1000
  • Pioneer SD-1100
  • Pioneer SA-600
  • Pioneer SA-800
  • 8675b299b1fb12e9707cc08fe535b1a4
  • Pioneer QA-800
  • Pioneer QC- 800
  • Pioneer QM-800
    • Picture: Pioneer Oscilloscope SD-1000 Front